1 Channel Control Unit with Temperature Measurement, incl. software

The Gelnorm®– Geltimer PST-1 evaluates all factors which influence the gel time of reaction resins such as type and quantity of hardener, accelerator, inhibitor, filler, pigments, as well as temperature and moisture. The instrument is easy to operate and normally no maintenance necessary.

The principle of measurement of Gelnorm®– Geltimer is simple: A stamper made of aluminium or stainless steel performs an up-down cycle in a test tube filled with resin. When the point of gelation is reached, the test tube is pulled up by the stamper. This stops the clock which was started at the beginning of the experiment and the gel time can be read of. With the probe temperature system the exothermic reaction can be measured. The electrical heating device, option heating block GT, can be controlled directly with the internal temperature controller.

Temperature control for the electrical heating block GT

Actual value (Pt100) Range: 0,0 °C ... 250,0 °C, adjustable and calibrated
Accuracy ± 0,3% of full scale ± 1 digit
Set value Range: 0,0 °C ... 200,0 °C (on request 250,0 °C)
Resolution 0,1 K
Load output power max. - resistive load : maximum 600 W

 

Temperature measurement for the sample

Sensor Thermocouple type K (Ni- CrNi) , EN 60 584
Connector Mini connector type K thermocouples, EN 60 584
Range 0,0 °C … 400,0 °C
Accuracy ± 1,5°C including cold-junction compensation

 

Time

Display LCD, 12mm
Start Button with status indicator
Stop optical switch
Range up to 99HH: 59MM: 59SS
Accuracy ± 1 second / 2 hours

DIN 16 945 page 1, DIN 16 919, DIN EN ISO 9396 and DIN EN 14022 method 5

PST-1 847.07 KB 08.05.2017

Offer

Device*
Ungültige Eingabe

Company*
Ungültige Eingabe

Title*
Ungültige Eingabe

First Name
Ungültige Eingabe

Name*
Ungültige Eingabe

Adress*
Ungültige Eingabe

ZIP Postal Code*
Ungültige Eingabe

City*
Ungültige Eingabe

Country*
Ungültige Eingabe

E-Mail*
Ungültige Eingabe

Message
Ungültige Eingabe

Code*
Code
  AktualisierenUngültige Eingabe

  

 

Adress

Gel Instrumente AG
Bahnhofstrasse 28
9242 Oberuzwil
Switzerland

Tel.  +41 71 950 28 82
Fax +41 71 950 28 84
E-Mail: This email address is being protected from spambots. You need JavaScript enabled to view it.

We have 19 guests and no members online

  • 1
  • 2
  • 3
  • 4